What is the matter with the screw air compressor showing low voltage

1

The screw air compressor shows low voltage, which is a problem often encountered in actual operation. For users of screw air compressors, understanding the causes of this phenomenon and knowing how to deal with it is the key to ensure stable operation of the equipment and improve production efficiency. In this article, OPPAIR will explore in depth the reasons why the screw air compressor shows low voltage and give corresponding solutions.

First of all, we need to understand the basic working principle of the screw air compressor. The screw air compressor is a process of air intake, compression and discharge through the mutual meshing of the yin and yang rotors, and in the process of the change of the rotor tooth volume. In this process, the stability of the voltage is crucial to the normal operation of the equipment. If the voltage is too low, it will directly affect the compression efficiency and service life of the screw air compressor.

 So, what are the reasons why the rotary air compressor shows low voltage? We can analyze it from the following aspects:

 1. Power line failure. The power line is the main way for the screw air compressor to obtain electricity. If the line has problems such as power outage and unstable voltage, the screw air compressor will show low voltage. This fault may be caused by a variety of reasons such as line aging, poor contact, short circuit, etc. To solve this kind of problem, it is necessary to check the power line to ensure that the line is unobstructed, the contact is good, and the voltage is stable.

 2. The voltage stabilizer is damaged. The voltage stabilizer is an important device for stabilizing the voltage in the screw air compressor. If the voltage stabilizer is damaged, the voltage of the equipment will be unstable, resulting in low voltage. In this case, the voltage stabilizer needs to be replaced in time to ensure the stability of the equipment voltage.

 3. The input voltage is too low. In addition to the problems of the power line and the voltage stabilizer, the input voltage itself is too low, which is also one of the reasons why the compresor de tornillo displays low voltage. This may be caused by grid voltage fluctuations, insufficient transformer capacity, etc. To solve this problem, it is necessary to check the grid voltage. If the grid voltage is normal, it may be that the transformer capacity is insufficient and a larger capacity transformer needs to be replaced.

 4. Internal equipment failure. Some key components inside the compresores de aire, such as the controller, motor, etc., may also cause low voltage if they fail. For example, there is low or high voltage protection inside the controller. If it is not set correctly, it may cause a false alarm of low voltage. Motor damage may cause the current to increase and the voltage to decrease. Such problems require professional inspection and repair.

 For the above reasons, we can take the following measures to solve the problem of low voltage displayed by the screw air compressor:

 First, check the power lines regularly to ensure that the lines are unobstructed and in good contact. For aging lines, they should be replaced in time. At the same time, pay attention to check the working status of the voltage stabilizer. If there is any abnormality, it should be repaired or replaced in time.

 Secondly, configure the transformer reasonably to ensure that the grid voltage can meet the needs of the compresseur d'air . If the grid voltage fluctuates greatly, you can consider installing an automatic voltage regulator to stabilize the voltage.

 Finally, for internal faults of the equipment, professionals need to be asked to inspect and repair. During the maintenance process, pay attention to check whether the controller settings are correct and whether the motor is damaged.

 In addition to the above measures, we can also reduce the probability of low voltage displayed by the hava kompresr by optimizing the equipment operating environment and improving the equipment maintenance level. For example, keeping the equipment operating environment dry and clean, and regularly cleaning the dust and debris inside the equipment can improve the heat dissipation effect of the equipment and reduce voltage fluctuations. At the same time, strengthening the daily maintenance and care of the equipment, timely discovering and dealing with potential problems, can also effectively extend the service life of the equipment.

 In short, the low voltage displayed by the screw air compressor is an issue that needs our attention. By deeply understanding its causes and taking effective countermeasures, we can ensure the stable operation of the equipment, improve production efficiency, and provide strong guarantees for the development of the enterprise.

 OPPAIR is looking for global agents, welcome to contact us for inquiries

 WeChat/ WhatsApp: +86 14768192555 

#Electric Rotary Screw air Compressor #Screw Air Compressor With Air Dryer #High Pressure Low Noise Two Stage Air Compressor Screw #All in one screw air compressors#Skid mounted laser cutting screw air compressor(#oil cooling screw air compressor


Post time: May-17-2025