The normal water temperature is 45-65℃.For≥70℃,customization is needed.Voltage:220V50Hz IP/220V60Hz IP

Model Air compressor Airflow Work pressure Recovery efficiency Output heat Water inlet Water outlet Water output Oil volume
kW m³/min bar % kW/h Standard °C Standard °C Standard kg/h L
HR-20 15 2.4 8.5 81.6 12.2 25 55 351 6.5
HR-25 18.5 3.13 8.5 81.6 14.7 25 55 421 7.8
HR-30 22 3.5 8.5 81.6 18 25 55 515 9.6
HR-50 37 6.38 8.5 81.6 30.2 25 55 866 16.1
HR-60 45 7.6 8.5 81.6 36.7 25 55 1053 15.1
HR-75 55 9.42 8.5 81.6 44.9 25 55 1287 16.2
HR-100 75 12.4 8.5 81.6 61.2 25 55 1754 17.6
HR-125 90 16.4 8.5 81.6 73.4 25 55 2105 21.2
HR-150 110 20.2 8.5 81.6 89.8 25 55 2573 25.9
HR-175 132 24.1 8.5 81.6 107.7 25 55 3088 31
HR-200 160 29.9 8.5 81.6 130.6 25 55 3743 37.6
HR-250 185 35.1 8.5 81.6 151.0 25 55 4328 43.5
HR-275 200 37.9 8.5 81.6 163.2 25 55 4678 47
HR-300 220 40.2 8.5 81.6 179.5 25 55 5146 51.7
HR-350 250 46.6 8.5 81.6 204.0 25 55 5848 58.8
HR-375 280 52.2 8.5 81.6 228.5 25 55 6550 65.9
HR-420 315 58.1 8.5 81.6 257.0 25 55 7368 74.1
HR-475 355 66.5 8.5 81.6 289.7 25 55 8304 83.5
HR-530 400 73.7 8.5 81.6 326.4 25 55 9357 94.1
HR-600 450 80.5 8.5 81.6 367.2 25 55 10526 105.8
HR-660 500 91.1 8.5 81.6 408.0 25 55 11696 117.6
HR-775 580 105.6 8.5 81.6 473.3 25 55 13567 136.4

Oil and gas dual heat recovery

In the energy recovery system of a fuel-injected(micro-oil)screw air compressor,the heat in the compressed air

accounts for 14.9%of the total heat.Compressed air energy recovery is suitable for situations where the water inlet temperature is below 40℃.When the water inlet temperature is above 40℃,the exhaust temperature will rise,

generally about 5℃ higher than the water inlet temperature.

Model Air compressor Airflow Work pressure Recovery efficiency Output heat Water inlet Water outlet Water output Oil volume
kW m³/min bar % kW/h Standard °C Standard °C Standard kg/h L
HR-20 15 2.4 8.5 81.6 12.2 25 55 351 6.5
HR-25 18.5 3.13 8.5 81.6 14.7 25 55 421 7.8
HR-30 22 3.5 8.5 81.6 18 25 55 515 9.6
HR-50 37 6.38 8.5 81.6 30.2 25 55 866 16.1
HR-60 45 7.6 8.5 81.6 36.7 25 55 1053 15.1
HR-75 55 9.42 8.5 81.6 44.9 25 55 1287 16.2
HR-100 75 12.4 8.5 81.6 61.2 25 55 1754 17.6
HR-125 90 16.4 8.5 81.6 73.4 25 55 2105 21.2
HR-150 110 20.2 8.5 81.6 89.8 25 55 2573 25.9
HR-175 132 24.1 8.5 81.6 107.7 25 55 3088 31
HR-200 160 29.9 8.5 81.6 130.6 25 55 3743 37.6
HR-250 185 35.1 8.5 81.6 151.0 25 55 4328 43.5
HR-275 200 37.9 8.5 81.6 163.2 25 55 4678 47
HR-300 220 40.2 8.5 81.6 179.5 25 55 5146 51.7
HR-350 250 46.6 8.5 81.6 204.0 25 55 5848 58.8
HR-375 280 52.2 8.5 81.6 228.5 25 55 6550 65.9
HR-420 315 58.1 8.5 81.6 257.0 25 55 7368 74.1
HR-475 355 66.5 8.5 81.6 289.7 25 55 8304 83.5
HR-530 400 73.7 8.5 81.6 326.4 25 55 9357 94.1
HR-600 450 80.5 8.5 81.6 367.2 25 55 10526 105.8
HR-660 500 91.1 8.5 81.6 408.0 25 55 11696 117.6
HR-775 580 105.6 8.5 81.6 473.3 25 55 13567 136.4

DRY OIL-FREE SCREW/ CENTRIFUGAL PET AIR COMPRESSOR ENERGY RECOVERY SYSTEM

Based on your on-site conditions and actual needs,feel free to contact us anytime.We will create professional

solutions tailored to your application scenarios to help reduce your investment costs,shorten the payback period, and achieve efficient energy savings.

Model Air compressor Air flow range Work pressure Energy recovery Output
kW m³/min MPa kW/h Hot water °C Chilled water °C Steam MPa
HR-1 22 – 250 5 – 80 0.3 – 0.65 21 – 236 30 – 95 5 – 20 0.1 – 0.35
HR-2 200 – 500 50 – 120 0.3 – 0.65 189 – 472 30 – 95 5 – 20 0.1 – 0.35
HR-3 400 – 900 120 – 200 0.3 – 0.65 377 – 849 30 – 95 5 – 20 0.1 – 0.35
HR-4 800 – 1800 150 – 300 0.3 – 0.65 754 – 1697 30 – 95 5 – 20 0.1 – 0.35
HR-5 1600 – 3500 250 – 600 0.3 – 0.65 1509 – 3301 30 – 95 5 – 20 0.1 – 0.35
HR-6 3000 – 8000 500 – 3000 0.3 – 0.65 2829 – 7544 30 – 95 5 – 20 0.1 – 0.35
HR-7 6500 – 18000 2500 – 8000 0.3 – 0.65 6130 – 16974 30 – 95 5 – 20 0.1 – 0.35
HR-8 16000 – 25000 5000 – 15000 0.3 – 0.65 15088 – 23575 30 – 95 5 – 20 0.1 – 0.35
11-19-img

Single oil heat recovery

1Heating 1 tonne of water by 1 °C requires 1,000 kcal of energy.

2Bath water is stored at 50 °C; average annual make-up water is 25 °C.

3Diesel: 10,300 kcal/kg, density 0.86 kg/L, price ¥7.0/L.

41 kWh of electricity yields 860 kcal of heat energy.

5Recoverable power per hour: 2 × 110 kW × 70 % × 95 % = 146.3 kW

6Daily recoverable heat: 146.3 × 860 kcal × 24 h × 90 % = 2,717,668.8 kcal (90 % allows an average 10 % heat loss)

7Hot water at 50 °C: 2,717,668.8 ÷ 1,000 ÷ 25 °C ≈ 108 tonnes per day

8Diesel replaced: 2,717,668.8 ÷ 10,300 ÷ 95 % ≈ 277.7 kg/day, i.e. 8.33 t per month and about 100 t per year

9Fuel cost avoided: 8.33 t × 1,190 L/t × ¥7.0 ≈ ¥69,389 per month, ¥833,000 per year


  • Previous:
  • Next:

  • Shandong OPPAIR Machinery Manufacturing Co.,Ld base in Linyi Shandong, anAAA-level enterprise with high-quality service and integrity in China.
    OPPAIR as one of the world’s largest air compressor system suppliers, currently developing the following products: Fixed-speed Air Compressors, Permanent Magnet VariableFrequency Air Compressors, Permanent Magnet Variable Frequency Two-stage Air Compressors, 4-IN-1 Air Compressors (lntegrated Air Compressor for Laser Cutting Machine)Supercharger, Freeze Air Dryer, Adsorption Dryer, Air Storage Tank and related accessories.

    993BEC2E04DB5C262586D8C5A979F5E35209_rawf1e11c91204f6666d7e94df86578eeabIMG_4308IMG_4329IMG_5177IMG_7354

    OPPAIR air compressor products are deeply trusted by customers.

    The company has always operated in good faith in the direction of customer service first, integrity first, and quality first. We hope you will join the OPPAIR family and welcome you.

    1 (1)1 (2)1 (3)1 (4)1 (5) 1 (6) 1 (7) 1 (8) 1 (9) 1 (10)  1 (12) 1 (13) 1 (14) 1 (15) 1 (16) 1 (17) 1 (18) 1 (19) 1 (20) 1 (21) 1 (22)1 (11)